Mikrotron EOSENS GE CAMERA Spezifikationen Seite 11

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 37
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 10
Initial setup EoSens GE Camera Manual
5 Initial setup
The EoSens is delivered with initial parameters and therefore does not need to be configured
via the serial link.
5.1 Serial number and firmware revision
Serial number and firmware revision is provided in EoSens non volatile memory and can be
read via software. The serial number is also marked on the type plate of the camera.
5.2 PowerUpProfile
The PowerUpProfile is the content of all camera registers to be loaded from non-volatile
memory after power up.
5.3 Camera profile
The actual set of parameters is called Camera Profile. All changes of parameters by the serial
link is reflected in the Camera Profile. On command the Camera Profile is saved to 4 user
profiles or the PowerUpProfile. It is loaded from the PowerUpProfile, 4 user profiles or 4
factory profiles. The camera profile is volatile and must be stored to the PowerUpProfile to be
reactivated on next power up.
5.4 Factory profiles
The factory profiles can be read but not written by the user. They are factory preset to the
settings described below.
Profile
Nr.
Video
data
width
/Mbyte/s
resolution
/ pixel
Image
frequency
/fps
0 92 640x480 300
1 106 1280x1024 81
2 31 640x480 100
3 26 1280x1024 20
Seitenansicht 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 36 37

Kommentare zu diesen Handbüchern

Keine Kommentare

Sharper Image Filtry powietrza podręczniki użytkownika

Zaczynanie od P

Kliknij na poniższy alfabet, aby przejść do pełnej listy modeli zaczynających się od tej litery

Modele Rodzaj dokumentu
Professional Plus
Instrukcja Użytkownika   now [en] , 12 strony
Instrukcja Użytkownika   Xerox Nuvera® 100/120/144 EA Production System Put Your Best, 12 strony