Configuration MC13xx Users Manual Rev. 1.08
image size
100x100 240x240 640x480 1280x1024
Senso rclock (MHz) 66 33 13,2 6,6
Time/line [µs] 2,06 4,12 10,3 20,6
Frames/s 4.852 1.011 202 47
Table 6.8-2
6.8.3 Synchronous operation without shutter
Without electronic shutter the exposure time is 1 / frame rate.
6.8.4 Synchronous operation with shutter
In the sensor is implemented a freeze frame shutter, which allows to reduce the exposure time in steps
of one line. The minimum value of the exposure time is the duration of 2 line periods, which is deter-
mined by the value of r2 (min. 001h).
Command: :r2<x
2
x
1
x
0
>
<x
2
x
1
x
0
> ... Range 001h ...3ffh
Response: none
Exposure time T
B
:
Tt
B
= r2 • T
ZZ
-T
ZZ
/ 2
T
B
... exposure time in s
r2 ... value of register 2
T
ZZ
... time/line
T
zz
= 1/F
sens
* 136 [s]
Tt
zz
... Time/line
F
sens
... sensor clock
Typical exposure times:
Sensor clock
frequency (MHz)
Zeit/Zeile
(µsec)
r2
bei 1/5.000 s
r2
bei 1/10.000 s
66 2,06 97 49
33 4,12 49 24
13,2 10,3 19 10
6,6 20,6 10 5
Table 6.8-3
6.8.5 Frame rate with asynchronous exposure
The frame rate with asynchronous exposure = Frame rate with synchronous exposure – (1 / exposure
time).
6.8.6 Asynchronous exposure, shutter control by pulse width
This operating mode is selected with register 6:
:r6[7..4] = 0xb
20
Exposure time depends on the width of the external EXP – signal.