Configuration MC132x Users Manual Rev. 0.23
23
Frame rate = 1/(exposure time + image output time). Image output time equals the selected free running
frame rate. Use MC13xx camera configuration tool for selection.
The following registers select exposure type:
Register Bits :r6[7..4] :r7[8] :rf[0]
camera stop xxx0 x x
Synchronous without elec-
tronic shutter
0001 0 0
Synchronous with electronic
shutter
0011 0 0
Synchronous with electronic
shutter and external synchro-
nisation signal, positive edge
0011 0 1
Synchronous with electronic
shutter and external synchro-
nisation signal, negative edge
0011 1 1
Asynchronous, pulsewidth,
positive edge
1011 0 0
Asynchronous, pulsewidth,
negative edge
1011 1 0
Asynchronous, timer, positive
edge
1111 0 0
Asynchronous, timer, nega-
tive edge
1111 1 0
Table 6.7-1
6.7.2 Frame rate with synchronous exposure
The frame rate with synchronous exposure is direct proportional to the selected number of lines.
The time for one line is:
T
zz
= 1/F
sens
• 136 [sec]
T
zz
...time/line
F
sens
... Sensorclock
Frame rate: = 1 / (time/line • number of lines+1) or:
= F
sens
/ (136 • (r3[9..0] +2))
Dependencies between image size and frame rate for typical clock frequencies are given in the follow-
ing table:
image size
100x100 240x240 640x480 1280x1024
Sensorclock (MHz) 66 33 13,2 6,6
Time/line [µs] 2,06 4,12 10,3 20,6
Frames/s 4.852 1.011 202 47
Table 6.7-2
6.7.3 Synchronous operation without shutter
Without electronic shutter the exposure time is 1 /
frame rate.