Configuration MC132x Users Manual Rev. 0.23
24
6.7.4 Synchronous operation with shutter
In the sensor is implemented a freeze frame shutter, which allows to reduce the exposure time in steps
of one line. The minimum value of the exposure time is the duration of 2 line periods, which is deter-
mined by the value of r2 (min. 001h).
Command: :r2<x
2
x
1
x
0
> <x
2
x
1
x
0
> ... Range 001h ...3ffh
Response: ACK if enabled by separate command :A<n>
Exposure time T
B
:
Tt
B
= r2 • T
ZZ
-T
ZZ
/ 2
T
B
... exposure time in s B
r2 ... value of register 2
T
ZZ
... time/line
T
zz
= 1/F
sens
* 136 [s]
Tt
zz
... Time/line
F
sens
... sensor clock
Typical exposure times:
Sensor clock
frequency (MHz)
Time/line
(µsec)
r2
@ 1/5.000 s
r2
@ 1/10.000 s
66 2,06 97 49
33 4,12 49 24
13,2 10,3 19 10
6,6 20,6 10 5
Table 6.7-3
6.7.5 External synchronisation with synchronous exposure
MC132x cameras can be synchronized to an external signal that is input on the EXP (TRIG) signal. The
strobe output signal of a MC132x “master camera” can be used for that purpose.
See timing diagram: Synchronous exposure with external synchronisation via TRIG
The cameras frame rate must be set to a frequency slightly higher than the maximum frequency of the
synchronization signal. The minimum frequency should be higher than 30Hz.
Command: :rf001 000 … deselect external sync signal
001 … select external sync signal
This is an example for enabling this function. Depending on the wanted camera
mode it can be necessary to add additional bits of this register .
Response: ACK if enabled by separate command :A<n>
Command: :rf001
<0> ... deselect external sync signal
<1> ... select external sync signal
Response: ACK if enabled by separate command :A<n>
Kommentare zu diesen Handbüchern